TKD CABLE
  • Alternative TKD KAWEFLEX 6120 SK-PUR Control Cable

Alternative TKD KAWEFLEX 6120 SK-PUR Control Cable

As highly flexible connection and control cable for high electrical and normal mechanical requirements in cable drag chains and motion drive systems in machine and plant construction. 

EMAILEMAIL:info@aein-cable.com

Product introduction
  • 01 Product application As highly flexible connection and control cable for high electrical and normal mechanical requirements in cable drag chains and motion drive systems in machine and plant construction. 
  • 02 Product characteristics low adhesion, silicone-free oilresistant acc. to DIN EN 60811-404 (only mineral oil) and largely resistant to grease, coolant fluids and lubricantsFlame retardant acc. to IEC 60332-1-2, CSA FT4, UL Vertical Tray Flame Test
    UV-resistant
  • 03 Technical certification

    conform to RoHS conform to 2014/35/EU-Guideline ("Low-Voltage Directive") CE

    We are pleased to produce special versions, other dimensions, core and jacket colours on request.

Product structure
Conductor material: Bare copper strand
Conductor class: Acc. to DIN VDE 0295 class 6 pt. 4 resp. IEC 60228 cl. 6 pt. 4
Core insulation: PVC
Core identification: Acc. to DIN VDE 0293 black wires with white numerals, 1 x GNYE
Overall stranding: Cores stranded in layers
Outer sheath: PUR
Sheath colour: Grey RAL 7001
Rated voltage: Acc. to IEC: 300/500 V | acc. to UL: 600 V
Testing voltage: 4 kV
Conductor resistance: At +20 °C acc. to DIN VDE 0295 cl. 6 resp. IEC 60228 cl. 6
Insulation resistance: At +20 °C ≥ 20 MΩ x km
Current-carrying-capacity: Acc. to DIN VDE
Min. bending radius fixed: 4 x d
Min. bending radius moved: 7,5 x d < 10 m TL | 10 x d ≥ 10 m TL
Operat. temp. fixed min/max: -40 °C / +80 °C
Operat. temp. moved min/max: -5 °C / +80 °C
Burning behavior: Flame-retardant acc. to IEC 60332-1-2, FT1
Approvals: UL/CSA - cURus 600V, 80°C
Speed: Self-supporting: max. 6 m/s, gliding: max. 3 m/s
Acceleration: Max. 10 m/s²